The hearth requirements for the Nectre 15 and Mark I is a piece of cement sheet 7mm thick with 5mm tiles on top. The hearth must extend a minimum of 300mm in front of the firebox. The Mark 2 Pedestal may be placed directly onto a combustible floor however a 300mm hearth must extend from the front of the pedestal. The Mk 2 legs has the same hearth requirements as the Mk 1.
The Megar requires a 12mm thick fibre cement sheet ( thermal conductivity 0.41 W/m degree K ) extending 650mm in front and 200mm to the sides of the firebox door opening.
An Australian standard Flue Kit to A52918 fitted with a Flue Shield is required to obtain the specified clearances.
Note: Installation of the NECTRE inbuilt must be in an existing masonry fireplace to comply with A52918. Consult your dealer for details of installation requirements.
NECTRE TEST REPORTS
| AS2918 (Clearance) |
| NEC 15 | (AMDEL) | M1563/87 | |
| MK I | (AMDEL) | M4731/88 | |
| MK II | (AMDEL) | M5512/89 | L4402/94 |
| B/OVEN | AMDEL) | L1244/93 | |
| MEGA | (AMDEL) | 8AM1370 | |
| A54013 (Emissions) |
| NEC 15 | M7840/92 | CERTNo. | E001/0793 |
| MK I | M7990/92 | CERTNo. | E002/0793 |
| MK II | L2659/93 | CERTNo. | EQ45/0394 |
| INBUILT | L600/93 | CERTNo. | E1O/0793 |
| MEGA | exempt | CERTNo. | E1O/0793 |
In the interest of product development, Pecan Engineering reserve the right to change product specifications without notice.
NECTRE DIMENSIONS FREE STANDING (millimetres..mm)
| | Height | Width | Depth | Door Aperture | Flue Diam. | Weight (Kg)
|
Nectre 15 Legs Ped. |
660 730 | 460 | 480 | 250 x 320 | 150 | 90 |
Mark 1 Legs Ped. | 680 710 | 725 | 480 | 250 x 495 | 150 | 120 |
Mark 2 Legs Ped. | 690 725 | 750 | 510 | 250 x 495 | 150 | 160 |
| B/Oven | 825 | 550 | 500 | 250 x 320 | 150 | 120 |
| Mega Legs Ped. | 760 830 | 760 | 620 | 265 x 505 | 150 | 200 |
NECTRE DIMENSIONS INBUILT
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
| Clearance in mm. | Nectre 15 | Mark 1 | Mark 2 | B/Oven | Mega |
| A | 200 | 150 | 75 | 125 | 450 |
| A | 750 | 700 | 350 | 350 | 650 |
| B(with side shield) | | 400 | | | |
| C(Hearth) | 750 | 900 | | 750 | 1100 |
| D(Hearth) | 900 | 850 | | 925 | 650 |
CORNER INSTALLATION (millimetres)
| E | | | 125 | 350 | 400 |
| E (with side shield) | 200 | 250 | | | |
|